System and management
Use the console when introducing new authentication methods. Verify a new administrator session before removing an existing working access path.
Security boundaries
Read the authentication and synchronization reference before changing accounts, AAA, TOTP or HA transport. It covers privilege revocation, password compatibility, persistent replay protection, sign-in lockouts and legacy-sync migration.
A management listen address does not restrict ingress interfaces. Test explicit destination ACLs from every untrusted segment. HA is experimental; policy sync and flow-state sync are distinct authenticated services, not proof of failover readiness.
Hostname
Change the hostname in the candidate, review it and apply it. Confirm a temporary remote change before persisting it.
set system hostname fw-a
Login accounts
Provision each administrator’s own SSH public key; keep the private key on that administrator’s device. The example assumes an account named alice.
set system login alice ssh-key <public-key>
Use the complete public-key line in place of the placeholder. Test login from a second session before altering the original account.
SSH daemon
Restrict the SSH listener to the management address and use the intended port. Test a separate administrator login.
set services ssh port 2222
set services ssh listen-address 10.0.0.1
HA config sync
Shared configuration and per-member identities must stay distinct. Use the HA mode and enrollment runbook for two-member enrollment and peer authority.
The receiver honors its local Web listener address and port even with the interactive Web UI disabled. A secret alone leaves the default loopback listener; explicitly configure a reachable control address on each member. Preserve receiver-local identity and review the legacy revision migration before upgrading.
HA conntrack sync
A standby needs compatible policy and current replicated state for an established flow to continue. Check replica readiness on both members before a maintenance failover.
State replication requires an explicit 32–1024-byte config-sync secret and at least one state peer. Unsigned UDP and listen-only replication are disabled. Authenticated framed TCP provides integrity, not confidentiality; isolate or encrypt the control link. Migration and transport details.
A second factor
Enroll the user’s TOTP device and test it with a synchronized appliance clock before relying on it.
set system login alice totp generate
Where a password is checked
External authentication can use RADIUS, LDAP or TACACS+. Keep a tested local recovery account and apply authentication changes with a confirmation window.
RADIUS
Configure the server address, timeout and a site-issued shared secret under set system aaa radius. Verify authentication and role mapping with a test account.
LDAP
Configure the endpoint, base DN and TLS under set system aaa ldap. This is a simple bind as the authenticating user, not a service-account directory search. Verify certificate trust and local group mapping; do not silently fall back to plaintext.
TACACS+
Configure the designated server and its shared secret under set system aaa tacacs. This integration authenticates users; it does not implement server-side TACACS+ authorization or accounting. Verify the locally configured group permissions as well as successful login.
Who gets in, and what they may do
Check the group assigned to the account, including any configurable default for directory users.
set system aaa default-group operators
The serial console
Match the console device and speed to the attached terminal or BMC console.
set system console device ttyS0
set system console speed 115200
How far back you can roll
Set the archive retention to the number of configuration revisions your change process needs.
set system commit-revisions 100
A history of the box itself
Enable local metrics collection when trends over time are needed in addition to live counters.
set system metrics enable true
Keyboard, locale and timezone
Match the console keyboard, locale and timezone to the operating environment. Verify the layout before entering a sensitive credential.
set system keyboard de
set system locale de_DE.UTF-8
set system timezone Europe/Berlin
When the clock cannot be trusted
Check synchronization before investigating suspicious timestamps, certificate validity or time-based login failures.
clock: 2021-01-14 03:22:57 UTC — NOT synchronised: no time source has set
this clock, so log timestamps, certificate expiry and time-based
rules are all unreliable
Check the result
sentinel show version
sentinel show system commit
Check time synchronization before testing a time-based factor. Inspect revision history before restoring an older configuration.